DocumentCode :
2086854
Title :
Control parameter selection in auxiliary resonant commutated pole converters
Author :
Teichmann, R.
Author_Institution :
ABB Corporate Res., Ladenburg, Germany
Volume :
2
fYear :
2001
fDate :
2001
Firstpage :
862
Abstract :
This paper addresses the optimum selection of the boost current and threshold current control parameters for the ARCP soft switching technique. The parameters are derived based on a minimization of the output voltage distortion induced by the ARCP operation. The impact of the proper selection of the resonant parameters on the system design is discussed
Keywords :
commutation; electric current control; resonant power convertors; switching circuits; 100 kVA; 400 V; ARCP soft switching technique; auxiliary resonant commutated pole converters; auxiliary resonant commutated pole soft switching; boost current parameters; control parameter selection; equivalent circuit; output voltage distortion minimisation; threshold current control parameters; Capacitors; Resonance; Resonant inverters; Snubbers; Switches; Switching circuits; Threshold current; Voltage control; Zero current switching; Zero voltage switching;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics Society, 2001. IECON '01. The 27th Annual Conference of the IEEE
Conference_Location :
Denver, CO
Print_ISBN :
0-7803-7108-9
Type :
conf
DOI :
10.1109/IECON.2001.975870
Filename :
975870
Link To Document :
بازگشت