DocumentCode :
2088190
Title :
A preliminary study of the effect of electrode placement in order to define a suitable location for two electrodes and obtain sufficiently reliable ECG signals when monitoring with wireless system
Author :
Hyung Wook Noh ; Yongwon Jang ; Lee, I.B. ; Yoonseon Song ; Ji-Wook Jeong ; Sooyeul Lee
Author_Institution :
Electron. & Telecommun. Res. Inst. in Korea (ETRI), Daejeon, South Korea
fYear :
2012
fDate :
Aug. 28 2012-Sept. 1 2012
Firstpage :
2124
Lastpage :
2127
Abstract :
Most countries face high and increasing rates of cardiovascular disease. Each year, heart disease kills more Americans than cancer. Therefore, there has been a promising market for portable ECG equipment and it is increasing. To use portable ECG measuring devices, it is essential to define a suitable location for the measuring as we need to reduced electrode size and distance. This research proposes to study how the inter-electrode distance affects the signal and how the electrode pair should be placed on the chest in order to obtain a sufficiently reliable ECG signal to detect heart arrhythmias in any environment, such as home or work. Therefore, we developed a compact, portable patch type ambulatory ECG monitoring system, Heart Tracker, using a microprocessor for preliminary study of signal analysis. To optimize the electrode arrangement in wireless environment, we compared HT and standard 12 lead with changing electrode position.
Keywords :
biomedical electrodes; cardiovascular system; diseases; electrocardiography; medical signal processing; microcomputer applications; patient monitoring; portable instruments; Heart Tracker; ambulatory ECG monitoring system; cardiovascular disease; chest; electrode arrangement; electrode location; electrode placement; electrode position; electrode size; heart arrhythmias; heart disease; inter-electrode distance; microprocessor; portable ECG equipment; portable ECG measuring devices; reliable ECG signals; signal analysis; wireless system monitoring; Bluetooth; Electrocardiography; Electrodes; Heart; Monitoring; Standards; Wireless communication; Algorithms; Diagnosis, Computer-Assisted; Electrocardiography, Ambulatory; Electrodes; Equipment Design; Equipment Failure Analysis; Humans; Pilot Projects; Reproducibility of Results; Sensitivity and Specificity; Signal Processing, Computer-Assisted; Telemetry;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
Conference_Location :
San Diego, CA
ISSN :
1557-170X
Print_ISBN :
978-1-4244-4119-8
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/EMBC.2012.6346380
Filename :
6346380
Link To Document :