Title :
Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone
Author :
Sungjun Kwon ; Hyunseok Kim ; Kwang Suk Park
Author_Institution :
Interdiscipl. Program of Bioeng., Seoul Nat. Univ., Seoul, South Korea
fDate :
Aug. 28 2012-Sept. 1 2012
Abstract :
As a smartphone is becoming very popular and its performance is being improved fast, a smartphone shows its potential as a low-cost physiological measurement solution which is accurate and can be used beyond the clinical environment. Because cardiac pulse leads the subtle color change of a skin, a pulsatile signal which can be described as photoplethysmographic (PPG) signal can be measured through recording facial video using a digital camera. In this paper, we explore the potential that the reliable heart rate can be measured remotely by the facial video recorded using smartphone camera. First, using the front facing-camera of a smartphone, facial video was recorded. We detected facial region on the image of each frame using face detection, and yielded the raw trace signal from the green channel of the image. To extract more accurate cardiac pulse signal, we applied independent component analysis (ICA) to the raw trace signal. The heart rate was extracted using frequency analysis of the raw trace signal and the analyzed signal from ICA. The accuracy of the estimated heart rate was evaluated by comparing with the heart rate from reference electrocardiogram (ECG) signal. Finally, we developed FaceBEAT, an iPhone application for remote heart rate measurement, based on this study.
Keywords :
electrocardiography; face recognition; feature extraction; independent component analysis; medical signal processing; photoplethysmography; skin; smart phones; video cameras; video recording; ECG; FaceBEAT; built-in camera system; cardiac pulse; cardiac pulse signal; detected facial region image; digital camera; electrocardiogram signal; facial video recording; feature extraction; frequency analysis; front facing-camera; heart rate extraction validation; iPhone application; independent component analysis; low-cost physiological measurement; photoplethysmographic signal; pulsatile signal; remote heart rate measurement; skin color change; smartphone camera; video imaging; Cameras; Electrocardiography; Error analysis; Face; Green products; Heart rate; Reliability; Algorithms; Cellular Phone; Diagnosis, Computer-Assisted; Electrocardiography, Ambulatory; Equipment Design; Equipment Failure Analysis; Face; Heart Rate; Humans; Photography; Reproducibility of Results; Sensitivity and Specificity;
Conference_Titel :
Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
Conference_Location :
San Diego, CA
Print_ISBN :
978-1-4244-4119-8
Electronic_ISBN :
1557-170X
DOI :
10.1109/EMBC.2012.6346392