• DocumentCode
    2088910
  • Title

    The Test of Inner-flue Tube Wall Temperature of Superheater Based on the Power Plant SIS

  • Author

    Yanzhi, Yu ; Liangbo, Zhang ; Haichuan, Xu ; Duogang, Chen ; Gongjun, Dong ; Bo, Shen ; Sheng, Liu

  • Author_Institution
    Sch. of Power & Mech. Eng., Wuhan Univ., Wuhan, China
  • Volume
    4
  • fYear
    2010
  • fDate
    14-15 Aug. 2010
  • Firstpage
    208
  • Lastpage
    211
  • Abstract
    Superheater and reheater tube failures were mostly due to excessive temperature, the inner-flue tube wall temperature of superheater make certain of tube thermal stress, material creep status and residual lifespan of tubes. So investigation of superheater safety began with experimentation of inner-flue tube wall temperature of superheater. In order to precisely learn inner-flue tube wall temperature of superheater of 600MW supercritical boiler, new measuring points are set on the superheater tube wall inner the flue. Since the working condition of 600MW supercritical boiler is quite severe, the temperature measuring points can only be used for short-term test. The data acquisition can be carried out automatically and a data storage system is required. The testing method in this paper transmit the measuring signal to the database of the thermal power control system through the redundant channel of the system. This method only requires new measuring points (thermocouple). The test data can be loaded directly from the SIS database, which saves not only money but also the work.
  • Keywords
    boilers; heat transfer; information systems; power engineering computing; data acquisition; data storage system; inner-flue tube wall temperature; material creep status; power 600 MW; power plant SIS; reheater tube failure; supercritical boiler; superheater failure; supervision information system; thermal power control system; tube thermal stress; Boilers; Electron tubes; Power generation; Temperature distribution; Temperature measurement; Testing; SIS database; inner tube wall; supercritical boiler; superheater; temperature testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Information Engineering (ICIE), 2010 WASE International Conference on
  • Conference_Location
    Beidaihe, Hebei
  • Print_ISBN
    978-1-4244-7506-3
  • Electronic_ISBN
    978-1-4244-7507-0
  • Type

    conf

  • DOI
    10.1109/ICIE.2010.340
  • Filename
    5572722