Abstract :
Cement plants are looking at automating the myriad of things to cut production costs and improve quality. In the QC department at the Leamington Plant a decision was made to use the newly developed online light scattering technology to control cement fineness. The online analyzer installation contributed to a record cement production year in 1999 by tightening control of the cement fineness. In November of 1998 a real time particle size analyzer was purchased from Malvern/Insitec and installed on the finish milling system. This paper describes the online analyzer and its implementation at the plant. The operating experience with the analyzer is discussed
Keywords :
cement industry; light scattering; particle size measurement; quality control; Ash Grove; Leamington Utah Plant; Malvern/Insitec; cement fineness control; cement plants; finish milling system; on line particle size analyzer; online analyzer installation; online light scattering technology; production costs reduction; quality improvement; Ash; Cement industry; Cities and towns; Costs; Fasteners; Instruments; Principal component analysis; Process control; Production; Signal processing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Cement Industry Technical Conference, 2000 IEEE-IAS/PCA
Conference_Location :
Salt Lake City, UT
ISSN :
1079-9931
Print_ISBN :
0-7803-5823-6
Type :
conf
DOI :
10.1109/CITCON.2000.848529
Filename :
848529
Link To Document :
بازگشت