    Estimation of central aortic pressure waveform features derived from the brachial cuff volume displacement waveform

  • Author

    Butlin, Mark ; Qasem, Ahmed ; Avolio, Alberto P.

  • Author_Institution
    Australian Sch. of Adv. Med., Macquarie Univ., Sydney, NSW, Australia
  • fYear
    2012
  • fDate
    Aug. 28 2012-Sept. 1 2012
  • Firstpage
    2591
  • Lastpage
    2594
  • Abstract
    There is increasing interest in non-invasive estimation of central aortic waveform parameters in the clinical setting. However, controversy has arisen around radial tonometric based systems due to the requirement of a trained operator or lack of ease of use, especially in the clinical environment. A recently developed device utilizes a novel algorithm for brachial cuff based assessment of aortic pressure values and waveform (SphygmoCor XCEL, AtCor Medical). The cuff was inflated to 10 mmHg below an individual´s diastolic blood pressure and the brachial volume displacement waveform recorded. The aortic waveform was derived using proprietary digital signal processing and transfer function applied to the recorded waveform. The aortic waveform was also estimated using a validated technique (radial tonometry based assessment, SphygmoCor, AtCor Medical). Measurements were taken in triplicate with each device in 30 people (17 female) aged 22 to 79 years of age. An average for each device for each individual was calculated, and the results from the two devices were compared using regression and Bland-Altman analysis. A high correlation was found between the devices for measures of aortic systolic (R2=0.99) and diastolic (R2=0.98) pressure. Augmentation index and subendocardial viability ratio both had a between device R2 value of 0.82. The difference between devices for measured aortic systolic pressure was 0.5±1.8 mmHg, and for augmentation index, 1.8±7.0%. The brachial cuff based approach, with an individualized sub-diastolic cuff pressure, provides an operator independent method of assessing not only systolic pressure, but also aortic waveform features, comparable to existing validated tonometric-based methods.
  • Keywords
    blood pressure measurement; blood vessels; regression analysis; AtCor Medical; Bland-Altman analysis; SphygmoCor XCEL; augmentation index; brachial cuff volume displacement waveform; central aortic pressure waveform feature estimation; clinical setting; diastolic blood pressure; noninvasive estimation; operator independent method; proprietary digital signal processing; radial tonometric based system; regression analysis; subendocardial viability ratio; transfer function; Arteries; Blood pressure; Brachytherapy; Estimation; Hypertension; Indexes; Pressure measurement; Adult; Aged; Arterial Pressure; Blood Pressure Determination; Female; Humans; Male; Middle Aged; Young Adult;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6346494
  • Filename
    6346494