DocumentCode :
2091225
Title :
Axial stereovision: modelization and comparison between two calibration methods
Author :
Rodin, V. ; Ayache, A.
Author_Institution :
ENSEEIHT, Toulouse, France
Volume :
2
fYear :
1994
fDate :
13-16 Nov 1994
Firstpage :
725
Abstract :
In passive binocular stereovision, there are generally two approaches: the lateral stereovision and the axial stereovision. The authors present a study relating more particularly to axial stereovision. Most of the works on axial stereovision have been theoretical. These studies have not been followed by real experiments because their authors could not produce a practical description of an axial stereovision system. The present authors propose a method to get a real axial stereovision system by calibration then by rectification. They also compare their axial stereovision system calibration method to the only one serious calibration process they found in the existing papers
Keywords :
calibration; optical design techniques; optical images; stereo image processing; axial stereovision; calibration methods; comparison; modelization; passive binocular stereovision; rectification; Calibration; Cameras; Image segmentation; Information retrieval; Lenses; Nonlinear optics; Optical computing; Robustness; Solid modeling;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Image Processing, 1994. Proceedings. ICIP-94., IEEE International Conference
Conference_Location :
Austin, TX
Print_ISBN :
0-8186-6952-7
Type :
conf
DOI :
10.1109/ICIP.1994.413666
Filename :
413666
Link To Document :
بازگشت