DocumentCode
2091677
Title
Development of the micro pump using ICPF actuator
Author
Guo, Shuxiang ; Nakamura, Tatsuya ; Fukuda, Toshio ; Oguro, Keisuke
Author_Institution
Dept. of Mech. Eng., Mie Univ., Tsu, Japan
Volume
1
fYear
1997
fDate
20-25 Apr 1997
Firstpage
266
Abstract
In this paper, we propose a new prototype model of a micro pump using an ICPF (ionic conducting polymer film) actuator as the servo actuator. This micro pump consists of two one-way valves that make use of the same ICPF actuator. The overall size of this micro pump prototype is 12 mm in diameter and 20 mm in length. The actuating mechanism is as follows. (1) The ICPF actuator as the diaphragm is bent into the anode side by application of electricity. Then the volume of the pump chamber increases, resulting in the inflow of liquid from the inlet to the chamber. (2) By changing the current direction, the volume of the pump chamber decreases, resulting in liquid flow from the chamber to the outlet. (3) The ICPF actuator is put on a sine voltage, the micro pump provides liquid flow from the inlet to the outlet. The characteristics of the micro pump are measured. The experimental results indicate that the micro pump has satisfactory responses
Keywords
actuators; ionic conductivity; micropumps; polymer films; valves; 12 mm; 20 mm; actuating mechanism; ionic conducting polymer film actuator; micro pump; one-way valves; servo actuator; Electrostatic actuators; Fluid flow; Medical diagnostic imaging; Micropumps; Piezoelectric actuators; Polymer films; Prototypes; Safety; Servomechanisms; Valves;
fLanguage
English
Publisher
ieee
Conference_Titel
Robotics and Automation, 1997. Proceedings., 1997 IEEE International Conference on
Conference_Location
Albuquerque, NM
Print_ISBN
0-7803-3612-7
Type
conf
DOI
10.1109/ROBOT.1997.620049
Filename
620049
Link To Document