• DocumentCode
    2091836
  • Title

    Plasmon excitation on a metal grating and its phase detection based biosensor application

  • Author

    Ziqian Luo ; Suyama, Takuro ; Okuno, Yoshihiro

  • Author_Institution
    Centre for Opt. & Electromagn. Res., South China Normal Univ., Guangzhou, China
  • fYear
    2012
  • fDate
    7-10 Nov. 2012
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    A grating-based biosensor via phase detection is stated. The resolution will be 10-7 RIU in the state-of-the-art today. The workspace can be shifted in a large range while the sensor resolution can remain in a high level by only changing the incident angle.
  • Keywords
    biosensors; diffraction gratings; excited states; optical sensors; plasmons; refractive index; 10-7 RIU; biosensor application; grating-based biosensor; incident angle; large ranged-workspace; metal grating; phase detection; plasmon excitation; sensor resolution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Communications and Photonics Conference (ACP), 2012 Asia
  • Conference_Location
    Guangzhou
  • ISSN
    2162-108X
  • Print_ISBN
    978-1-4673-6274-0
  • Type

    conf

  • Filename
    6510720