DocumentCode
2092815
Title
The determination of the total flavonoids by UV and a flavone glycoside by HPLC in Torreya grandis Fort Leaves
Author
Dai, Rongji ; Jiang, Dan ; Li, Wei ; Zhang, Yongqian ; Yu, Yuhong ; Deng, Yulin ; Meng, Weiwei
Author_Institution
Beijing Inst. of Technol., Beijing
fYear
2007
fDate
23-27 May 2007
Firstpage
1887
Lastpage
1891
Abstract
A UV method was established to determination the total flavonoids in extractive solution from Torreya grandis Fort, leaves, and a RP-HPLC method was developed and validated to quantify 4´, 5, 7-Trihydroxyflavone- 5- O- [alpha- L- Rhamno-pyranosyl- (1rarr4)- 6- O- acetyl- beta- D- glucopyranoside] (FRG). The dried leaf samples were extracted using methanol. The extracts were directly analyzed, without any purification, on a reversed-phase ODS column (250 mm times 4.6 mm, 5mum) with acetonitrile-phosphate aqueous (pH 3.8) isocratic elution and the detection was carried out by UV at 330 nm. The UV method showed excellent linearity, precision and accuracy. The standard curve for total flavonoids was linear over the range of 4-18 mug-m-1 (R2 = 0.9995). The HPLC method was validated for linearity, precision, accuracy, limit of detection and quantification. The standard curve for FRG was linear over the range of 0.39 mug - 3.53 mug (R2 = 0.9998). This method showed excellent repeatability (relative standard deviation, R.S.D. < 2.0%), precision(R.S.D. = 1.4%) and accuracy(102.27; R.S.D. = 1.02%). The limits of detection (LOD) of FRG, based on a detector signal-to-noise ratio of 3, were 0.065 mg ml-1 and the lowest levels tested in Torreya grandis Fort, leaves by this procedure (limit of quantification, LOQ) were 0.196 mg m-1.This assay can be readily utilized as quality controlled method for Torreya grandis Fort preparations.
Keywords
biochemistry; chromatography; organic compounds; spectrochemical analysis; ultraviolet spectra; FRG; HPLC; Torreya grandis Fort leaves; UV spectroscopic chemical analysis; acetonitrile-phosphate aqueous isocratic elution; extractive solution; flavone glycoside; flavonoids; reversed-phase ODS column; Anti-bacterial; Chemical engineering; Chemical technology; Detectors; Linearity; Methanol; Petroleum; Purification; Signal to noise ratio; Testing; FRGs Determination; HPLC; Total flavonoids; UV; Validation;
fLanguage
English
Publisher
ieee
Conference_Titel
Complex Medical Engineering, 2007. CME 2007. IEEE/ICME International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4244-1077-4
Electronic_ISBN
978-1-4244-1078-1
Type
conf
DOI
10.1109/ICCME.2007.4382076
Filename
4382076
Link To Document