Title :
Failure mechanism of three-level power amplifier for active magnetic bearings
Author :
Zhou Dan ; Zhu Changsheng
Author_Institution :
Coll. of Electr. Eng., Zhejiang Univ., Hangzhou, China
Abstract :
The switching power amplifiers with high efficiency are often required in active magnetic bearings, but they have some problems due to the switching process. In fact, the control current in the switching power amplifiers is superimposed with a considerable number of higher harmonics. The three-level PWM modulation was proposed to obtain smaller current ripples or lower harmonics. However, three-level PWM modulation was found to be failure under some conditions and the failure had seriously affected its application. The failure mode and failure mechanism are in detail studied in this paper. Meanwhile, the methods for reducing such failure in the three-level switching power amplifiers are suggested.
Keywords :
magnetic bearings; power amplifiers; pulse width modulation; active magnetic bearings; failure mechanism; failure mode; switching power amplifiers; switching process; three-level PWM modulation; three-level power amplifier; Coils; Failure analysis; Magnetic levitation; Power amplifiers; Pulse width modulation; Switches; Active Magnetic Bearings; Failure Mechanism; Power Amplifier; Three-level;
Conference_Titel :
Control Conference (CCC), 2010 29th Chinese
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-6263-6