Title :
Four terminal, optically isolated, zero crossing AC relay
Author_Institution :
Motorola Inc., Phoenix, Arizona
Abstract :
This paper describes a scheme for controlling ac power by non-mechanical means. An electronic relay is implemented utilizing photon flux, rather than magnetic flux, as the coupling agency between the input and output terminals. In order to ndnimize electromagnetic interference (EMI), relay actuation is only permitted during the zero voltage excursions of the ac source. A triac functions as the output contacts.
Keywords :
Detectors; Junctions; Logic gates; Relays; Switches; Thyristors; Trigger circuits;
Conference_Titel :
Power Electronics Specialists Conference, 1973 IEEE
Conference_Location :
Pasadena, California, USA
DOI :