DocumentCode :
2098265
Title :
Four terminal, optically isolated, zero crossing AC relay
Author :
Mazur, Thomas
Author_Institution :
Motorola Inc., Phoenix, Arizona
fYear :
1973
fDate :
11-13 June 1973
Firstpage :
159
Lastpage :
162
Abstract :
This paper describes a scheme for controlling ac power by non-mechanical means. An electronic relay is implemented utilizing photon flux, rather than magnetic flux, as the coupling agency between the input and output terminals. In order to ndnimize electromagnetic interference (EMI), relay actuation is only permitted during the zero voltage excursions of the ac source. A triac functions as the output contacts.
Keywords :
Detectors; Junctions; Logic gates; Relays; Switches; Thyristors; Trigger circuits;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 1973 IEEE
Conference_Location :
Pasadena, California, USA
ISSN :
0275-9306
Type :
conf
DOI :
10.1109/PESC.1973.7065184
Filename :
7065184
Link To Document :
بازگشت