DocumentCode
2098802
Title
Analysis on Energy Consumption and Optimal Operation of FGD System in Power Plant
Author
Xu, Gang ; Yang, Yongping ; Wang, Nan ; Yuan, Xing ; Li, Ji ; Song, Xiaona
Author_Institution
Key Lab. of Condition Monitoring & Control for Power, Plant Equip. of Minist. of Educ., North China Electr. Power Univ., Beijing, China
fYear
2010
fDate
28-31 March 2010
Firstpage
1
Lastpage
4
Abstract
This paper analyzed the energy consumption characteristics of typical limestone-gypsum wet flue gas desulfurization (FGD) system which is widely used in power plant for SOx removal, and discussed its optimal operation. In the FGD system, booster fan; circulating slurry pump and oxidation fan are three major energy consuming devices. We established the mathematical models to disclose the relationship between the energy consumption and the desulfurization features of these equipments. On this basis, we obtained the performance curve of these equipments and proposed the optimal operation ways of the FGD system. The promising results obtained here provide a new approach for desulfurization with low energy consumption.
Keywords
air pollution control; energy consumption; fans; flue gas desulphurisation; fuel pumps; steam power stations; sulphur compounds; FGD system optimal operation; booster fan; circulating slurry pump; energy consumption; limestone-gypsum wet flue gas desulfurization; oxidation fan; power plants; sulphur oxide removal; Absorption; Blades; Boilers; Condition monitoring; Energy consumption; Flue gases; Oxidation; Power generation; Power system modeling; Slurries;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Engineering Conference (APPEEC), 2010 Asia-Pacific
Conference_Location
Chengdu
Print_ISBN
978-1-4244-4812-8
Electronic_ISBN
978-1-4244-4813-5
Type
conf
DOI
10.1109/APPEEC.2010.5448640
Filename
5448640
Link To Document