• DocumentCode
    2099056
  • Title

    Flowrate measurement of gas/liquid two-phase flow base on the double-cone flowmeter

  • Author

    Xie, Dailiang ; Zhu, Yue ; Tao, Shan

  • Author_Institution
    Coll. of Metrol. Technol. & Eng., Jiliang Univ., Hangzhou, China
  • fYear
    2011
  • fDate
    10-12 May 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In this paper, the experimental studies were conducted on the gas/liquid two-phase flow by using a new double-cone flowmeter with diameter ratio of 0.8 in the 50mm-diameter horizontal pipe. The discharge coefficient of the double-cone flowmeter was calibrated by experimental methods in the water standard facility. The homogeneous model and the James model were applied to measure total flowrate of the gas/liquid two-phase flow, and the measurement errors were analyzed. A modified homogeneous model was proposed. The experimental results show that relative error of the modified model is within 6%, which indicates that the new model is effective to the total flowrate measurement. At the same time, it may prove that the double-cone flowmeter can be used in gas/liquid two-phase flow measurement.
  • Keywords
    flow measurement; flowmeters; two-phase flow; James model; discharge coefficient; double-cone flowmeter; flowrate measurement; gas/liquid two-phase flow; homogeneous model; horizontal pipe; measurement errors; water standard facility; Equations; Fluid flow measurement; Mathematical model; Phase measurement; Pipelines; Sea measurements; double-cone flowmeter; flowrate; gas/liquid two phase flow; measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2011 IEEE
  • Conference_Location
    Binjiang
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4244-7933-7
  • Type

    conf

  • DOI
    10.1109/IMTC.2011.5944211
  • Filename
    5944211