Abstract
Spatial quadrature and speckle tracking are both techniques which extend the estimation of flow velocity or tissue motion velocity to two or three dimensions. The authors applied both under similar experimental conditions to assess and compare their performance. They also describe a new spatial quadrature processor that obviates the need for axial alignment under conditions of mixed axial-lateral flow. This processor avoids the estimate bias produced by jitter in the axial alignment step previously described, and thus allows the non-axial component(s) of flow to be tracked without sacrificing axial resolution. In the authors´ flow experiment, summed radiofrequency echo data were captured in an M-mode scan geometry using 2:1 parallel receive processing in both spatial quadrature and two-beam speckle tracking configurations using a 7.5 MHz linear array and a modified commercial ultrasound scanner. Laminar flow was established in a wall-less vessel phantom using a computer-controlled pump. The authors captured echo data from this phantom at beam-vessel angles of 60° and 90° (i.e. pure lateral flow). These data were processed off-line to estimate flow velocity profiles. Volume flow rates were calculated from these profiles by integration. The mean volume flow rates estimated with 2-D speckle tracking agreed with the known flow rates with a maximum relative error of 7% for true lateral flow and 10% for mixed axial-lateral flow. The equivalent values for spatial quadrature were 5% and 15%
Keywords
biomedical ultrasonics; blood flow measurement; demodulation; laminar flow; speckle; 2-D speckle tracking; 7.5 MHz; M-mode scan geometry; axial resolution; beam-vessel angle; computer-controlled pump; flow tracking techniques comparison; jitter; linear array; mixed axial-lateral flow; modified commercial ultrasound scanner; phase-sensitive axial demodulation; pure lateral flow; spatial quadrature; speckle tracking; wall-less vessel phantom; Computational geometry; Data flow computing; Demodulation; Imaging phantoms; Motion estimation; Phase estimation; Scattering; Spatial resolution; Speckle; Tracking;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 1999. Proceedings. 1999 IEEE
Conference_Location
Caesars Tahoe, NV
ISSN
1051-0117
Print_ISBN
0-7803-5722-1
Type
conf
DOI
10.1109/ULTSYM.1999.849275
Filename
849275
Link To Document