  • Abstract
    The purpose of this study is to assess the effect of different noise reduction filters on ultrasound images. In particular two denoising filters based on mathematical morphology and wavelet transform are proposed. Simulation results show that the techniques developed increase the image quality and then allow a more accurate diagnosis. This work was carried out in collaboration with Taranto (Italy) Hospital. Thanks to the staff of this sanitary structure it has been possible to get the necessary material for the correct development of the simulation algorithm and the sample images on which the algorithm has been applied and verified.
  • Keywords
    biomedical ultrasonics; image denoising; medical image processing; ultrasonic imaging; wavelet transforms; B-mode ultrasound medical images; Taranto Hospital; denoising filters; image quality; mathematical morphology; noise reduction; sanitary structure; simulation algorithm; ultrasound images; wavelet transform; Biomedical imaging; Indexes; Noise; Reactive power; Speckle; Transducers; Ultrasonic imaging; Ultrasound images; denoising filtering; image quality index; speckle noise;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2011 IEEE
  • Conference_Location
    Binjiang
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4244-7933-7
  • Type

    conf

  • DOI
    10.1109/IMTC.2011.5944261
  • Filename
    5944261