• DocumentCode
    2101324
  • Title

    Interlaboratory comparison of AC voltage ratio standards in the range up to 35 kV

  • Author

    Styblikova, Renata ; Kikalo, Valeriy ; Draxler, Karel ; Kopshyn, Vladimir

  • Author_Institution
    Dept. of Electromagn. Quantities, Czech Metrol. Inst., Prague, Czech Republic
  • fYear
    2011
  • fDate
    10-12 May 2011
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Measurements were carried out at the Czech Metrology Institute (CMI) and at the Ukraine National Institute Ukrmetrteststandart in the range of transformation ratios up to (6-35) kV/ 100 V, and the results were compared. The results are interesting due to the fact that the two laboratories used different methods for determining the ratio error and the phase displacement. The results are also atypical due to the fact that one value of the burden of the transfer transformer is approaching zero.
  • Keywords
    instrument transformers; measurement errors; measurement standards; voltage measurement; AC voltage ratio standard; Czech Metrology Institute; interlaboratory comparison; phase displacement; ratio error; transfer transformer; voltage 100 V; voltage 6 kV to 35 kV; Capacitors; Current measurement; Displacement measurement; Measurement uncertainty; Phase measurement; Uncertainty; Voltage measurement; comparison; compressed gas capacitor; instrument voltage transformer; phase displacement; ratio error; uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2011 IEEE
  • Conference_Location
    Binjiang
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4244-7933-7
  • Type

    conf

  • DOI
    10.1109/IMTC.2011.5944292
  • Filename