• DocumentCode
    2103485
  • Title

    The Optimized Match Method Enhances the Energy Efficiency Ratio (EER) of Room Air-Conditioner

  • Author

    Wang Zhiyuan ; He Tao ; Xu Zhiliang ; Luohao ; Dang Hongchang

  • Author_Institution
    Coll. of Vehicle & Power, Henan Univ. of Sci. & Technol., Luoyang, China
  • fYear
    2010
  • fDate
    28-31 March 2010
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    In this paper, an experimental study was conducted on domestic air-conditioner refrigeration system to increase the system energy efficiency ratio (EER). First, different types of high efficiency compressors were tested and selected. Second, inner-grooved copper tubes which had fins with hydrophilic membrane, together with the indoor and outdoor helical fans were employed to improve the heat convection efficiency. Third, the relationship between capillary´s optimum length and refrigerant charge quantity was confirmed experimentally. By these means, the system EER can reach up to 3.2, which meets the demands of National standards of China.
  • Keywords
    air conditioning; compressors; domestic appliances; fans; refrigeration; capillary optimum length; domestic air-conditioner refrigeration system; energy efficiency ratio; high efficiency compressors; hydrophilic membrane; indoor helical fans; inner-grooved copper tubes; optimized match method; outdoor helical fans; refrigerant charge quantity; room air-conditioner; Biomembranes; Compressors; Cooling; Copper; Energy consumption; Energy efficiency; Optimization methods; Refrigerants; Refrigeration; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Engineering Conference (APPEEC), 2010 Asia-Pacific
  • Conference_Location
    Chengdu
  • Print_ISBN
    978-1-4244-4812-8
  • Electronic_ISBN
    978-1-4244-4813-5
  • Type

    conf

  • DOI
    10.1109/APPEEC.2010.5448834
  • Filename
    5448834