DocumentCode
2103486
Title
Electro-Optic-Probe system response: experiment and simulation
Author
Cheng, H.J. ; Whitaker, J.F. ; Herrick, K.J. ; Dib, N. ; Katehi, L.P.B.
Volume
1
fYear
1995
fDate
4-4 Sept. 1995
Firstpage
151
Lastpage
154
Abstract
The frequency response of an extemal electro-optic probe has been determined, experimeritally and using finite-difference, time-domain simulations, to be extremely sensitve to both the elevation and permittivity of the probe. An analytical expression to correct for the system response of the probe has been tested. The use of low-permittivity EO polymers has also been proposed and demonstrated computationally.
Keywords
Calibration; Circuits; Computational modeling; Finite difference methods; Frequency measurement; Power system transients; Probes; Pulse measurements; Time domain analysis; Transmission line measurements;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference, 1995. 25th European
Conference_Location
Bologna, Italy
Type
conf
DOI
10.1109/EUMA.1995.336936
Filename
4137149
Link To Document