FIB lift-out STEM failure analysis technique
Author :
Stevie, F.A. ; Vartuli, C.B.
Author_Institution :
North Carolina State Univ., Raleigh, NC, USA
fYear :
2002
fDate :
2002
Firstpage :
157
Lastpage :
158
Abstract :
Device fabrication with reduced linewidths makes it possible for smaller defects to affect device performance. The availability of 5-7 nm diameter focused ion beams has made it possible to expose most defects of interest for analysis using EDS or AES. However, device dimensions have become so small that even the site specific capability of the FIB can be challenged. The beam current at 7 nm resolution is not sufficient to perform significant material removal, therefore larger diameter beams are required. Failure analysis techniques are often unable to locate the region of interest better than within a few tenths of a micron. As this region is sputtered using the FIB, frequent checks are made to determine if the feature is visible. Unfortunately, it is quite possible in the case of small features to essentially remove most if not all of the material so that elemental identification is not possible. To resolve this problem, a method was developed to combine the features of the FIB to prepare a specimen for lift-out and the features of a scanning transmission electron microscope (STEM). This allows the gathering of information from a specimen of a thickness that would not be viewable in a conventional TEM, but is resolvable with the STEM due to its unique lens configuration.
Keywords :
electron lenses; electron optics; failure analysis; focused ion beam technology; integrated circuit reliability; integrated circuit testing; scanning-transmission electron microscopy; specimen preparation; 5 to 7 nm; AES; EDS; FIB lift-out STEM failure analysis technique; FIB lift-out specimen preparation; FIB site specific capability; STEM lens configuration; beam current; beam diameter; beam resolution; defect size; device dimensions; device fabrication; device linewidth; elemental identification; failure analysis techniques; feature visibility; focused ion beams; material removal; scanning transmission electron microscope; Failure analysis; Image analysis; Information analysis; Instruments; Lenses; Probes; Scanning electron microscopy; Spectroscopy; Transmission electron microscopy; Vacuum systems;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Physical and Failure Analysis of Integrated Circuits, 2002. IPFA 2002. Proceedings of the 9th International Symposium on the
Print_ISBN :
0-7803-7416-9
Type :
conf
DOI :
10.1109/IPFA.2002.1025637
Filename :
1025637
Link To Document :
بازگشت