    Experience with a spider arm rim support failure on a large hydro generator

  • Author

    Bomben, S.G.

  • Author_Institution
    Ontario Power Generation, Niagara-on-the-Lake, ON
  • fYear
    2007
  • fDate
    22-24 Oct. 2007
  • Firstpage
    219
  • Lastpage
    223
  • Abstract
    With the average age of many generators approaching 50 years or more, it is increasingly important that routine inspections are done to identify any machine anomalies. Recently, at Ontario power generation, a routine inspection on one of the hydro pump generators revealed a very serious condition on the rotor spider that was unknown to exist before the inspection took place. Potential catastrophic results were avoided.
  • Keywords
    hydroelectric generators; inspection; pumps; rotors; Ontario power generation; hydro pump generators; rotor spider; routine inspections; spider arm rim support failure; Arm; Coils; Condition monitoring; Inspection; Nuclear power generation; Power generation; Pumps; Rivers; Rotors; Steel;