Title :
Monitoring and diagnosis of failures in squirrel-cage induction motors due to cracked or broken bars
Author :
Tommaso, A. O Di ; Miceli, R. ; Galluzzo, G. Ricco
Author_Institution :
Dept. of Electr., Electron. & Telecommun. Eng., Univ. of Palermo, Palermo, Italy
Abstract :
In this paper three diagnostic procedures, based on on the vibration, current and instantaneous power monitoring for the detection and monitoring of incipient faults as cracks or bar breaks on squirrel cage motors are briefly reminded. The experimental investigations, carried out at the SDESLab (Sustainable Development Energy Savings Laboratory) of the University of Palermo in order to underline merits and drawbacks of the methods applied to the same die cast squirrel cage induction motor, are presented. The results of the investigations confirmed the effectiveness of the diagnostic procedures here considered.
Keywords :
fault diagnosis; squirrel cage motors; SDESLab; Sustainable Development Energy Savings Laboratory; University of Palermo; broken bars; cracked bars; current monitoring; failure diagnosis; failure monitoring; instantaneous power monitoring; squirrel-cage induction motors; vibration monitoring; Bars; Circuit faults; Indexes; Induction motors; Rotors; Stators; Vibrations; Induction machines; broken rotor bar; fault diagnosis; squirrel cage;
Conference_Titel :
Diagnostics for Electric Machines, Power Electronics & Drives (SDEMPED), 2011 IEEE International Symposium on
Conference_Location :
Bologna
Print_ISBN :
978-1-4244-9301-2
Electronic_ISBN :
978-1-4244-9302-9
DOI :
10.1109/DEMPED.2011.6063599