DocumentCode
2107485
Title
2D-RAID-based array self-adaptation strategy
Author
Zhang, Ji ; He, Bing
Author_Institution
State Key Lab. of Virtual Reality Technol. & Syst., Beihang Univ., Beijing, China
fYear
2010
fDate
17-19 Dec. 2010
Firstpage
107
Lastpage
112
Abstract
This paper proposes a strategy which is able to improve the reliability of 2D-RAID array by reorganizing the effective disks left when some disks in the array fail, so as to reduce the potential impact from extra disk failures and effectually increase the reliability class of effective disks left in the array. In addition, this paper also shows how to use the strategy in 3×3 2D-RAID array and the transformation of 2D array to 1D array. The analysis on reliability shows that such strategy is able to increase the MTTDL (Mean time to data loss) of the array by 2 to 3 order of magnitudes.
Keywords
RAID; reliability; 2D array transformation; 2D-RAID array reliability; 2D-RAID based array self-adaptation strategy; disk failures; Arrays; Fault tolerance; Fault tolerant systems; Maintenance engineering; Markov processes; Mathematical model; 2D-RAID; Reorganization; Self-adaptation;
fLanguage
English
Publisher
ieee
Conference_Titel
Information Theory and Information Security (ICITIS), 2010 IEEE International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4244-6942-0
Type
conf
DOI
10.1109/ICITIS.2010.5689615
Filename
5689615
Link To Document