DocumentCode
2108356
Title
PD activity inside random wire wound motor stator insulation and early failures: A case study analysis
Author
Guastavino, F. ; Dardano, A. ; Torello, E. ; Massa, G.F.
Author_Institution
Naval & Electr. Eng. Dept., Univ. of Genova, Genova, Italy
fYear
2011
fDate
5-8 Sept. 2011
Firstpage
283
Lastpage
287
Abstract
This paper presents the outcome of a partial discharge test campaign performed on random wire wound stator insulation of electrical motors. The test campaign was carried out in the frame of a rewinding program involving some units that experienced early failures due to insulation breakdown. The cause of the early failures was targeted to the pollution of the motors due to the harsh environment. Besides the performance of the stator insulation was investigated in many conditions in order to check its compliance with the operating conditions and with the technical standard requirements.
Keywords
electric breakdown; electric motors; machine insulation; machine windings; stators; PD activity; electrical motors; insulation breakdown; partial discharge test campaign; random wire wound motor stator insulation; rewinding program; IEC standards; Insulation; Partial discharges; Pollution; Stator windings; Stress; Electrical insulation; Partial Discharges; Pulse width modulation; Rotating Machines;
fLanguage
English
Publisher
ieee
Conference_Titel
Diagnostics for Electric Machines, Power Electronics & Drives (SDEMPED), 2011 IEEE International Symposium on
Conference_Location
Bologna
Print_ISBN
978-1-4244-9301-2
Electronic_ISBN
978-1-4244-9302-9
Type
conf
DOI
10.1109/DEMPED.2011.6063637
Filename