Abstract :
An advanced imaginary- gamma /sub t/ lattice for the Fermilab Main Injector is examined for its response to quadrupole field errors, quadrupole misalignment errors, as well as its dynamical aperture. It is found that the lattice is tunable except near an integer tune. The misalignment sensitivity factors are acceptable and can be lowered if the low-beta triplet quadrupoles are specially aligned. The dynamical aperture is very large provided that a family of harmonic sextupoles is installed.<>
Keywords :
error analysis; magnetic fields; proton accelerators; Fermilab Main Injector; advanced imaginary- gamma /sub t/ lattice; dynamical aperture; harmonic sextupoles; misalignment sensitivity factors; quadrupole field errors; quadrupole misalignment errors; triplet quadrupoles; Educational institutions; Error correction; Lattices; Neodymium; Noise measurement; Stability;