  • Title

    Detection of airgap eccentricity for permanent magnet synchronous motors based on the d-axis inductance

  • Author

    Hong, Jongman ; Lee, Sang Bin ; Kral, Christian ; Haumer, Anton

  • Author_Institution
    Dept. of Electr. Eng., Korea Univ., Seoul, South Korea
  • fYear
    2011
  • fDate
    5-8 Sept. 2011
  • Firstpage
    378
  • Lastpage
    384
  • Abstract
    The majority of the work performed for detecting eccentricity faults for permanent magnet synchronous motors (PMSM) focus on motor current signature analysis (MCSA), as it provides continuous on-line monitoring with existing current sensors. However, MCSA cannot be applied under nonstationary conditions and cannot distinguish faults with load torque oscillations, which are limitations for many PMSM drive applications. In this paper, it is shown that the d-axis inductance, Ld, decreases with increase in the severity of eccentricity due to the change in the degree of magnetic saturation, and it is proposed as a new fault indicator. The inverter can be used to perform a standstill test automatically whenever the motor is stopped, to measure Ld for eccentricity testing independent of load variations or oscillations, which is not possible with MCSA. An FE and experimental study on a 10hp PMSM verifies that eccentricity can be detected independent of the load with high sensitivity and reliability.
  • Keywords
    air gaps; fault location; inductance; load (electric); machine testing; permanent magnet motors; synchronous motor protection; MCSA; PMSM drive application; air gap eccentricity; continuous online monitoring; current sensor; d-axis inductance; eccentricity fault detection; eccentricity testing; fault indicator; load torque oscillation; load variation; magnetic saturation; motor current signature analysis; nonstationary condition; permanent magnet synchronous motor; standstill test; Inductance; Magnetic circuits; Magnetic flux; Rotors; Saturation magnetization; Stator windings; Temperature measurement; Airgap Eccentricity; Condition Monitoring; Diagnostics; Magnetic Saturation; Motor Current Signature Analysis (MCSA); Permanent Magnet Synchronous Motor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Diagnostics for Electric Machines, Power Electronics & Drives (SDEMPED), 2011 IEEE International Symposium on
  • Conference_Location
    Bologna
  • Print_ISBN
    978-1-4244-9301-2
  • Electronic_ISBN
    978-1-4244-9302-9
  • Type

    conf

  • DOI
    10.1109/DEMPED.2011.6063651
  • Filename
    6063651