    The RatCAP (rat conscious animal PET) is a miniature positron emission tomography scanner intended for neurological and behavioral study of small awake animal. The RatCAP system comprises of three distinct modules: a rigid-flex technology based printed circuit board (PCB) which houses the detector components and front end application specific integrated circuit (ASIC), a time to digital converter and signal processing module (TSPM) which receives and processes ASIC signals and transmits processed data over two Giga bit fiber optic links to, finally, a PCI based data acquisition and control PCB (PACRAT). TSPM-3 is redesigned from previous versions to accommodate second generation front end ASIC and possible future two scanner expansions. ASIC´s programmable features are exploited using new additional TSPM electronics for scanner calibration and test. Designs of these three modules and corresponding firmware and software upgrades are complete. Results from a fully integrated next generation RatCAP on the bench are presented.
  • Keywords
    application specific integrated circuits; data acquisition; high energy physics instrumentation computing; neurophysiology; peripheral interfaces; positron emission tomography; printed circuits; solid scintillation detectors; ASIC; Giga bit fiber optic links; PCI based data acquisition; Printed Circuit Board; Rat Conscious Animal PET; RatCAP; TSPM electronics; TSPM-3; Time to Digital Converter and Signal Processing module; front end Application Specific Integrated Circuit; neurology; positron emission tomography scanner; real time data acquisition; rigid-flex technology; small awake animal; Animals; Application specific integrated circuits; Calibration; Control systems; Data acquisition; Electronic equipment testing; Integrated circuit technology; Positron emission tomography; Printed circuits; Real time systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Real-Time Conference, 2007 15th IEEE-NPSS
  • Conference_Location
    Batavia, IL
  • Print_ISBN
    978-1-4244-0866-5
  • Electronic_ISBN
    978-1-4244-0867-2
  • Type

    conf

  • DOI
    10.1109/RTC.2007.4382767
  • Filename
    4382767