• DocumentCode
    2110215
  • Title

    Non invasive assessment of carotid and femoral arterial pressure using B-mode ultrasound diameter waveforms

  • Author

    Graf, Sebastian ; Craiem, D. ; Armentano, Ricardo L.

  • Author_Institution
    CONICET, Argentina
  • fYear
    2012
  • fDate
    Aug. 28 2012-Sept. 1 2012
  • Firstpage
    5610
  • Lastpage
    5613
  • Abstract
    Non invasive local arterial blood pressure measurement has become a challenge over recent years. The aim of this study was to evaluate in a general population the validity of an alternative method to assess systolic local arterial blood pressure, from the analysis of B-mode diameter waveforms, and to estimate the accuracy when compared to carotid and femoral arterial tonometry. In 190 asymptomatic subjects (51±11 years, range: 24-73; pulse pressure: 51±11 mmHg, range: 31-93) systolic arterial pressure was obtained at the left carotid and left femoral artery by applanation tonometry (SBPCar_Ton and SBPFem_Ton) and by automatic analysis of B-mode echographic images, calibrated using an iterative exponential model. Tonometry and echocardiography-derived pressure estimates correlated significantly (R=0.99, p<;0.05). Mean difference between the two methods was only -2.5±5.0 mmHg for carotid artery (SBPCar_Ton: 122±18 mHg), and -2.1±5.7 mmHg for femoral artery (SBPFem_Ton: 134±21 mmHg), independent of pressure level. In conclusion, alternative method was found to allow an accurate and precise estimation of systolic local arterial pressure, with an underestimation error of ~2%.
  • Keywords
    blood pressure measurement; blood vessels; echocardiography; waveform analysis; B-mode echographic imaging; B-mode ultrasound diameter waveforms; automatic analysis; calibration; carotid arterial tonometry; carotid pressure; echocardiography-derived pressure estimation; femoral arterial pressure; femoral arterial tonometry; iterative exponential model; left carotid artery; left femoral artery; noninvasive local arterial blood pressure measurement; systolic local arterial blood pressure; underestimation error; Arteries; Blood pressure; Brachytherapy; Calibration; Market research; Ultrasonic imaging; Ultrasonic variables measurement; Adult; Aged; Carotid Arteries; Echocardiography; Female; Femoral Artery; Humans; Male; Manometry; Middle Aged;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6347266
  • Filename
    6347266