DocumentCode
2110788
Title
Integral control technique for single-phase UPS inverter
Author
Guerrero, Josep M. ; de Vicuna, Luis Garcia ; Miret, Jaume ; Matas, Jose ; Castilla, Miguel
Author_Institution
Dept. d´Eng. Sist, Univ. Politecnica de Catalunya, Barcelona
Volume
4
fYear
2002
fDate
2002
Firstpage
1043
Abstract
This paper proposes a reset integral control applied to a single-phase full-bridge DC-AC inverter. The reset integral control, also called one-cycle control, is a nonlinear feed-forward control technique, in which by integrating the filter input-voltage of a buck-type converter, it reaches a reference value in one switching cycle. In this case, the controller design based on a large-signal approach is introduced in order to achieve good transient response and stability in a wide range of parameter variations and high rejection of external disturbances. Besides, in spite of the nonlinear nature of the controller, we obtain a linear average output-voltage dynamic response. On the other hand, in a clear-cut contrast with current mode control, a current sensor is not required. The proposed control provides the following features: fast transient response, "clean" sine-wave output-voltage, fixed switching frequency, and high robustness against load and line step changes. In addition, two PWM pattern generators based on this control scheme are introduced: bipolar and unipolar PWM. The simulation results demonstrate the effectiveness of this control technique for inverters in UPS applications, especially, when nonlinear loads must to be supplied and line has large undesirable harmonic components.
Keywords
bridge circuits; dynamic response; electric current control; feedforward; invertors; nonlinear control systems; transient response; uninterruptible power supplies; PWM pattern generators; UPS inverter; bipolar PWM; buck-type converter; clean sine-wave output voltage; controller design; current mode control; current sensor; fast transient response; filter input-voltage; fixed switching frequency; high robustness; large-signal approach; line step changes; linear average output-voltage dynamic response; load changes; nonlinear feedforward control; one-cycle control; parameter variations; reset integral control; single-phase full-bridge DC/AC inverter; stability; switching cycle; transient response; unipolar PWM;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on
Print_ISBN
0-7803-7369-3
Type
conf
DOI
10.1109/ISIE.2002.1025931
Filename
1025931