DocumentCode
2111141
Title
Direct power control of three-phase PWM rectifier using space vector modulation-simulation study
Author
Kazmierkowski, Marian P.
Volume
4
fYear
2002
fDate
2002
Firstpage
1114
Abstract
This paper proposes a novel and simple direct power control of three-phase PWM rectifiers with constant switching frequency using space vector modulation (DPC-SVM). The active and reactive power is used as the pulse width modulated (PWM) control variables instead of the three-phase line currents usually used. Moreover, line voltage sensors are replaced by a virtual flux (VF) estimator. The theoretical principle of this method is discussed. The steady state and dynamic results of DPC-SVM that illustrate the operation and performance of the proposed system are presented. It is shown that DPC-SVM exhibits several features as: simple algorithm, good dynamic response, constant switching frequency and particularly provide sinusoidal line current when supply voltage is not ideal. Results have proven excellent performances and verify the validity of the proposed system.
Keywords
PWM power convertors; dynamic response; power control; reactive power; rectifying circuits; PWM control variables; active power control; constant switching frequency; direct power control; dynamic results; good dynamic response; reactive power control; sinusoidal line current; space vector modulation; steady state results; three-phase PWM rectifiers; virtual flux estimator;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on
Print_ISBN
0-7803-7369-3
Type
conf
DOI
10.1109/ISIE.2002.1025944
Filename
1025944