Title :
System Electronics and DAQ for the Silicon Vertex Detector Upgrade for PHENIX
Author_Institution :
Columbia Univ., New York
fDate :
April 29 2007-May 4 2007
Abstract :
The PHENIX experiment at RHIC will be upgraded with a silicon vertex detector (VTX). The VTX is comprised of 4 barrels of silicon detectors. The inner two barrels will be implemented with pixel detectors read out using the ALICE1LHCb readout chip. The pixel detectors and readout chips are mounted on a high density interconnect (PIXEL bus) allowing data to be read out at 10 MHz. The outer two barrels will be implemented with a novel stripixel sensor designed by the Brookhaven National Laboratory Instrumentation Division. Each stripixel sensor will be instrumented with 12 SVX4 readout chips and controlled by a custom ASIC designed at Oak Ridge National Laboratory allowing for high speed read out. We will report of the design and status of the read out and Data Acquisition system for PHENIX VTX detector.
Keywords :
data acquisition; nuclear electronics; position sensitive particle detectors; readout electronics; sensors; silicon radiation detectors; ALICE1LHCb; ASIC design; Brookhaven National Laboratory Instrumentation Division; Oak Ridge National Laboratory; PHENIX experiment; RHIC; Relativistic Heavy Ion Collider; data acquisition system; pixel detectors; readout chips; silicon vertex detector; stripixel sensor; Application specific integrated circuits; Data acquisition; Detectors; Instruments; Laboratories; Physics; Protons; Sensor arrays; Silicon; Spectroscopy;
Conference_Titel :
Real-Time Conference, 2007 15th IEEE-NPSS
Conference_Location :
Batavia, IL
Print_ISBN :
978-1-4244-0866-5
Electronic_ISBN :
978-1-4244-0867-2
DOI :
10.1109/RTC.2007.4382843