• DocumentCode
    2111548
  • Title

    Comparison of direct current control techniques for a three-phase shunt active power filter

  • Author

    Fnaiech, Farhat ; Al-Haddad, Kamal ; Yacoubi, L.

  • Volume
    4
  • fYear
    2002
  • fDate
    2002
  • Firstpage
    1217
  • Abstract
    This paper deals with a comparative study of the performance of three direct current control techniques applied to a three-phase shunt active power filter. The three considered techniques are: (i) direct current control (DCC) based on a PI regulator; (ii) DCC based on a sliding mode control (SMC); and (iii) DCC based on a SMC combined with a one step ahead prediction (SMC-P). These three regulators are used to calculate the estimated peak value of the line-current in the control loop. The criterion established for current controllers comparison is chosen to be the total harmonic distortion (THD) of the line-current. It is expected that the (SMC-P) technique will improve the performance, since it avoids unnecessary switching of the solid-state devices. Indeed, this technique makes switching decisions based on the average between sampled and one step ahead predicted DC voltage errors. Simulation results are presented using Power system Blockset (PSB) of Matlab.
  • Keywords
    active filters; control system analysis computing; control system synthesis; electric current control; harmonic distortion; power engineering computing; power harmonic filters; two-term control; variable structure systems; direct current control techniques; three-phase shunt active power filter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, 2002. ISIE 2002. Proceedings of the 2002 IEEE International Symposium on
  • Print_ISBN
    0-7803-7369-3
  • Type

    conf

  • DOI
    10.1109/ISIE.2002.1025963
  • Filename