DocumentCode :
2112000
Title :
Reduction of voltage harmonics for parallel-operated inverters
Author :
Zhong, Qing-Chang ; Blaabjerg, Frede ; Guerrero, Josep M. ; Hornik, Tomas
Author_Institution :
Dept. of Aeronaut. & Automotive Eng., Loughborough Univ., Loughborough, UK
fYear :
2011
fDate :
17-22 Sept. 2011
Firstpage :
473
Lastpage :
478
Abstract :
The inherent limitations of the conventional droop control scheme have recently been revealed and a robust droop controller to achieve exact proportional load sharing has been proposed. This paper continues the work with a strategy to improve the voltage quality so that the total harmonic distortion of the output voltage can be maintained small even when nonlinear loads are connected. Experimental results are provided to verify the analysis and design.
Keywords :
harmonic distortion; invertors; robust control; droop control scheme; nonlinear loads; parallel-operated inverters; proportional load sharing; robust droop controller; total harmonic distortion; voltage harmonics reduction; Accuracy; Harmonic analysis; Impedance; Inverters; Reactive power; Robustness; Voltage control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2011 IEEE
Conference_Location :
Phoenix, AZ
Print_ISBN :
978-1-4577-0542-7
Type :
conf
DOI :
10.1109/ECCE.2011.6063807
Filename :
6063807
Link To Document :
بازگشت