DocumentCode
2113136
Title
Management of combined manual and remote handling shutdowns at JET
Author
Edwards, P.K. ; Bell, A. ; Davies, N. ; Middleton, R. ; Pate, B. ; Pick, M. ; Tait, J.
Author_Institution
JET Joint Undertaking, Abingdon, UK
fYear
1999
fDate
1999
Firstpage
257
Lastpage
260
Abstract
The Tile Carrier Transfer Facility (TCTF) was used during the remote tile exchange for the robotic transfer of all equipment in and out of the torus using the short boom in coordination with the mascot and articulated boom. The TCTF has been up rated to support limited duration manned access to the torus where remote handling is impractical
Keywords
fusion reactor operation; fusion reactor safety; materials handling; nuclear reactor maintenance; telerobotics; JET; Joint European Torus; TCTF; Tile Carrier Transfer Facility; articulated boom; combined manual/remote handling shutdowns; fusion reactor; limited duration manned access; maintenance; mascot; remote tile exchange; robotic transfer; safety; short boom; Antenna measurements; Industrial control; Neutrons; Personnel; Phase estimation; Remote handling; Remote handling equipment; Robots; Silicon; Tiles;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1999. 18th Symposium on
Conference_Location
Albuquerque, NM
Print_ISBN
0-7803-5829-5
Type
conf
DOI
10.1109/FUSION.1999.849832
Filename
849832