• DocumentCode
    2113375
  • Title

    A generalized method for wind inverter control under unbalanced operating conditions

  • Author

    Wu, Shuang ; Stankovic, Ana Vladan

  • Author_Institution
    Electr. & Comput. Eng. Dept., Cleveland State Univ., Cleveland, OH, USA
  • fYear
    2011
  • fDate
    17-22 Sept. 2011
  • Firstpage
    865
  • Lastpage
    870
  • Abstract
    In this paper, a generalized method for a wind inverter control under unbalanced operating conditions is proposed. The control method presented in this paper provides complete harmonic elimination in line currents and DC link voltage with adjustable power factor. The method is general and can be used for all levels of imbalance in grid voltages and line impedances. Simulation results for a variable speed wind turbine system with PM synchronous generator connected to unbalanced grid voltages and line impedances are compared to results obtained by using a standard control of a grid side inverter. In addition, the proposed method has been verified for a grid-fault ride through control of the wind inverter.
  • Keywords
    harmonics suppression; invertors; permanent magnet generators; power factor; power generation control; power generation faults; power grids; synchronous generators; wind turbines; DC link voltage; PM synchronous generator; adjustable power factor; grid side inverter; grid-fault ride through control; harmonic elimination; line currents; line impedances; unbalanced grid voltages; variable speed wind turbine system; wind inverter control; Equations; Harmonic analysis; Inverters; Mathematical model; Power system harmonics; Torque; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Congress and Exposition (ECCE), 2011 IEEE
  • Conference_Location
    Phoenix, AZ
  • Print_ISBN
    978-1-4577-0542-7
  • Type

    conf

  • DOI
    10.1109/ECCE.2011.6063861
  • Filename
    6063861