• DocumentCode
    2113679
  • Title

    Dose rate around a primary cooling loop of the ITER plant with two different operational scenarios

  • Author

    Ianni, A. ; Lucci, F. ; Sandri, S. ; Vasselli, R. ; Pace, L. Di

  • Author_Institution
    ENEA IRP, Frascati, Italy
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    342
  • Lastpage
    345
  • Abstract
    To assess the activated corrosion products (ACP) inventories in the primary cooling loop of the ITER plant two operational scenarios are considered that have been studied in different approaches: the M5a and the BPP acp. Then external dose rates around the hot leg are calculated using the MCNP code and the resulting surface concentrations as source terms. A direct comparison of the dose rates calculated with both scenarios is made considering a specific component of the first wall loop. All the assessment procedure is described, from the ACP inventory evaluation to the dose rate calculation. Results are then discussed considering the radiological impact on the workers as well as the potential risk for the ACP inventory in the coolant (leakages and accidents)
  • Keywords
    Tokamak devices; cooling; corrosion; dosimetry; fusion reactor safety; BPP; ITER; M5a; MCNP; activated corrosion products; coolant; dose rate; primary cooling loop; radiological impact; surface concentration; Accidents; Coolants; Cooling; Corrosion; Hazards; Leg; Personnel; Potential well; Protection; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering, 1999. 18th Symposium on
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    0-7803-5829-5
  • Type

    conf

  • DOI
    10.1109/FUSION.1999.849853
  • Filename
    849853