DocumentCode
2114059
Title
Failure analysis and design improvement of the Alcator C-Mod toroidal field coil sliding joint
Author
Titus, Peter H. ; Becker, Herb ; Gwinn, David ; Rettman, Ken ; Stahle, Peter
Author_Institution
Stone & Webster Eng. Corp., Boston, MA, USA
fYear
1999
fDate
1999
Firstpage
427
Lastpage
432
Abstract
In March of 1998 a short occurred in the TF system. Small amounts of copper and carbon tracking were found in the A-right TF. A crack in a finger in the central column was also found. Subsequent disassembly revealed arcing damage to the outer-upper horizontal leg finger joint region, at the lead connection leg where the voltage difference is large. Material was also removed from the neighboring torque shell. Significant degradation of the felt metal in the inner fingers at the central column was also found. This initiated re-analysis of the finger design, testing of the felt metal, and a decision to replace all the felt metal in the machine. Design improvements have been made but some uncertainty as to the cause of the failure remains
Keywords
Tokamak devices; coils; cracks; electromagnets; failure analysis; fusion reactor design; Alcator C-Mod; C; Cu; central column; crack; failure; outer-upper horizontal leg finger joint; sliding joint; toroidal field coil; Assembly; Coils; Copper; Current density; Failure analysis; Fingers; Leg; Nuclear and plasma sciences; Torque; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Fusion Engineering, 1999. 18th Symposium on
Conference_Location
Albuquerque, NM
Print_ISBN
0-7803-5829-5
Type
conf
DOI
10.1109/FUSION.1999.849871
Filename
849871
Link To Document