DocumentCode :
2117731
Title :
Investigating a H control method considering frequency uncertainty for CLC type Inductively Coupled Power Transfer system
Author :
Dai, Xin ; Tang, Chunsen ; Sun, Yue ; Wang, Zhihui ; Hu, Aiguo Patrick
Author_Institution :
Autom. Coll., Chongqing Univ., Chongqing, China
fYear :
2011
fDate :
17-22 Sept. 2011
Firstpage :
2022
Lastpage :
2027
Abstract :
Based on Generalized State Space Averaging (GSSA) method, this paper realized the output control of an Inductively Coupled Power Transfer (ICPT) system with frequency uncertainty. The state variables in time domain were expanded to generalized state variables in frequency domain and the linear state space model was established. Using linear fractional transformation, the GSSA model was separated into certainty and uncertainty parts to acquire an expanded state space model with perturbation feedback. And a H-infinite robust control method was proposed. In addition, a mixed sensitivity robust controller in frequency domain was developed to eliminate steady state error. Experimental results verified the proposed control method.
Keywords :
H control; perturbation techniques; power control; robust control; state-space methods; CLC type; GSSA model; H∞ control method; H-infinite robust control method; coupled power transfer system; frequency domain; frequency uncertainty; linear fractional transformation; linear state space model; mixed sensitivity robust controller; perturbation feedback; state space averaging method; state variables time domain; Control systems; Frequency control; Frequency domain analysis; Resonant frequency; Steady-state; Uncertainty; Voltage control; GSSA; Uncertainty; robust control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2011 IEEE
Conference_Location :
Phoenix, AZ
Print_ISBN :
978-1-4577-0542-7
Type :
conf
DOI :
10.1109/ECCE.2011.6064035
Filename :
6064035
Link To Document :
بازگشت