DocumentCode
2118465
Title
Miniaturized thermal flow sensors with through silicon vias for flip-chip packaging
Author
Sosna, C. ; Kropp, M. ; Lang, W. ; Buchner, R.
Author_Institution
Inst. for Microsensors, -Actuators & -Syst., Univ. of Bremen, Bremen, Germany
fYear
2010
fDate
1-4 Nov. 2010
Firstpage
2460
Lastpage
2463
Abstract
We present the first miniaturized, high temperature stable thermal flow sensor with through silicon vias for electrical connection on the back of the silicon chip. The electrical and mechanical connections are done by standard flip-chip bonding to a printed circuit board which leads to a simpler packaging as compared to wire bonding. Moreover, the chip size could be further reduced without any loss of performance.
Keywords
flip-chip devices; flow measurement; flow sensors; lead bonding; printed circuits; silicon; temperature sensors; Si; electrical connection; flip-chip packaging; mechanical connection; miniaturized thermal flow sensor; printed circuit board; wire bonding;