DocumentCode
2120860
Title
SAR and induced current measurements on wired hands-free mobile telephones
Author
Porter, S.J. ; Capstick, M.H. ; Faraci, F. ; Flintoft, I.D. ; Marvin, A.C.
Author_Institution
York Univ., UK
fYear
2004
fDate
25-26 May 2004
Firstpage
9
Lastpage
13
Abstract
The aim of this work was to establish the level of SAR (specific absorption rate) within the head, associated with the use of hands free kits (HFKs) with GSM mobile telephones and to identify the principal factors determining the observed levels of SAR in order to better understand the observed levels. The work was funded as part of the UK government´s mobile telecommunications and health research programme in response to public concerns on the use of HFKs.
Keywords
biological effects of fields; electric current; electromagnetic wave absorption; mobile handsets; 1750 MHz; 888 MHz; GSM mobile telephones; HFK; SAR; hands free kits; induced current measurement; specific absorption rate; wired hands-free mobile telephones;
fLanguage
English
Publisher
iet
Conference_Titel
Antenna Measurements and SAR, 2004. AMS 2004. IEE
ISSN
0537-9989
Print_ISBN
0-86341-415-X
Type
conf
DOI
10.1049/ic:20040067