• DocumentCode
    2126493
  • Title

    Stochastic measurement of PWM signals

  • Author

    Pejic, D. ; Vujicic, V.

  • Author_Institution
    Fac. of Eng., Novi Sad, Yugoslavia
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    30
  • Lastpage
    31
  • Abstract
    Stochastic true RMS instrument has a wide frequency range, since it works with short data, implied by the use of two-bit flash AD converters and a two-bit multiplier-accumulator. Such a simple hardware allows easy multichannel measurement. Both of the above requirements, wide frequency range and necessity of multichannel measurements, are substantial in the case of measurements on PWM drives. It is shown that the stochastic instrument measures PWM voltages, currents, powers and energies, at the fundamental frequency of 50 Hz, with the same accuracy as their sinusoidal counterparts. This accuracy can be extremely high.
  • Keywords
    Analog-digital conversion; Measurement errors; Power measurement; Pulse width modulation; Signal processing equipment; Stochastic systems; 50 Hz; PWM drives; PWM signals; PWM voltages; frequency of 50 Hz; multichannel measurement; multichannel measurements; stochastic measurement; true RMS instrument; two-bit flash AD converters; two-bit multiplier-accumulator; wide frequency range; Current measurement; Data engineering; Energy measurement; Frequency measurement; Instruments; Measurement errors; Pulse width modulation; Shape measurement; Stochastic processes; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.850860
  • Filename
    850860