Abstract
The primary standard of the loss angle unit containing special capacitors and a transformer bridge, has been developed at VNIIM. Different methods for reproduction of the unit are used, the measurement results agree within 0.1 /spl mu/rad at the frequency 1 kHz. The measurement uncertainty is /spl plusmn/0.2 /spl mu/rad, k=2.
Keywords
Bridge circuits; Capacitors; Dielectric loss measurement; Measurement standards; Measurement uncertainty; 1 kHz; PP-capacitor method; bridge ratio arms; cross-capacitor method; load current compensation; loss angle unit; measurement uncertainty; primary standard; quadrature corrections; total uncertainty budget; transformer bridge; unit reproduction; Bridge circuits; Capacitance; Capacitors; Dielectric losses; Electrodes; Equations; Goniometers; Loss measurement; Measurement uncertainty; Standards development;