Abstract
The coil constant k/sub 0/-i.e. the quotient of magnetic flux density in the coil centre over the coil current-of a Garrett type field coil has been determined in units as maintained by various standard laboratories. Most of the laboratories have also measured the coil constant k(f) as function of frequency up to f=15 kHz.
Keywords
coils; constants; magnetic flux; magnetic variables measurement; transfer standards; 15 kHz; Garrett type field coil; coil centre; coil constant; coil current; field coil transfer standard; magnetic flux density; quotient of magnetic flux density; standard laboratories; Coils; Density measurement; Frequency; Laboratories; Magnetic field measurement; Magnetic flux density; Measurement standards; Nuclear magnetic resonance; Resistors; Temperature;