DocumentCode :
2129055
Title :
Comparison of the Josephson voltage standards of VNIIM and PTB
Author :
Behr, R. ; Niemeyer, J. ; Katkov, A.
Author_Institution :
Phys. Tech. Bundesanstalt, Braunschweig, Germany
fYear :
2000
fDate :
14-19 May 2000
Firstpage :
251
Lastpage :
252
Abstract :
Comparisons of the 1 V Josephson array voltage standard (JAVS) of the "D.I. Mendeleyev Institute for Metrology" (VNIIM), Russia, with that of the Physikalisch-Technische Bundesanstalt (PTB), Germany, were carried out in St. Petersburg in June 1999. The results of the direct comparison agree within an overall standard uncertainty of less than 1 nV. The results also show that direct comparisons are useful for detecting voltage offsets of a few parts in 10/sup 10/.
Keywords :
Josephson effect; Zener diodes; measurement standards; measurement uncertainty; voltage measurement; 1 nV; Josephson voltage standards; Mendeleyev Institute for Metrology; PTB; Physikalisch-Technische Bundesanstalt; VNIIM; Zener reference; direct comparison; indirect comparison; standard uncertainty; voltage offsets; Detectors; Frequency; Lead; Metrology; Oscillators; Signal generators; Switches; Thermal resistance; Uncertainty; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2000 Conference on
Conference_Location :
Sydney, NSW, Australia
Print_ISBN :
0-7803-5744-2
Type :
conf
DOI :
10.1109/CPEM.2000.850971
Filename :
850971
Link To Document :
بازگشت