• DocumentCode
    2129170
  • Title

    Establishment of 10-V Josephson array voltage standard

  • Author

    Kyu-Tae Kim ; Jinhee Kim ; Se Il Park ; Yang Sup Song

  • Author_Institution
    Korea Res. Inst. of Stand. & Sci., Taejon, South Korea
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    259
  • Lastpage
    260
  • Abstract
    The use of 10-V Josephson voltage standard based on 10-V array enables us more convenient and reliable 10-V calibration compared to 10:1 divider system at KRISS. Consistency between the two systems was successfully tested with using a 10-V Zener voltage standard. The uncertainty of the new 10-V Josephson array system was estimated to be less than 0.01/spl times/10/sup -6/(k=2).
  • Keywords
    Josephson effect; Zener diodes; calibration; measurement standards; superconducting junction devices; voltage dividers; voltage measurement; 10 V; 10 V standard; 10:1 divider; Josephson array voltage standard; KRISS; Zener voltage standard; calibration; uncertainty; Battery charge measurement; Calibration; Detectors; Measurement standards; Scattering; Sensor arrays; System testing; Time measurement; Uncertainty; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.850975
  • Filename
    850975