DocumentCode :
2129474
Title :
Accurate selective isotropic measuring system for electromagnetic fields in amplitude and phase
Author :
Jacquin, F. ; Nicolas, E.
Author_Institution :
Telediffusion de France, Metz, France
fYear :
2000
fDate :
14-19 May 2000
Firstpage :
287
Lastpage :
288
Abstract :
Broadcast towers are shared by numerous communication systems which generate a very complex electromagnetic environment, and have to comply with safety standards based on ICNIRP guidelines. To verify compliance with those limits, it is necessary to define a new selective isotropic and accurate probe.
Keywords :
broadcasting; calibration; electric field measurement; electric sensing devices; electromagnetic fields; phase measurement; safety; standards; ICNIRP guidelines; amplitude; broadcast towers; complex electromagnetic environment; electromagnetic fields; phase; safety standards; selective isotropic measuring system; selective isotropic probe; Antenna measurements; Broadcasting; Electromagnetic fields; Electromagnetic measurements; Electromagnetic scattering; Frequency; Magnetic field measurement; Phase measurement; Poles and towers; Probes;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2000 Conference on
Conference_Location :
Sydney, NSW, Australia
Print_ISBN :
0-7803-5744-2
Type :
conf
DOI :
10.1109/CPEM.2000.850989
Filename :
850989
Link To Document :
بازگشت