• DocumentCode
    2129474
  • Title

    Accurate selective isotropic measuring system for electromagnetic fields in amplitude and phase

  • Author

    Jacquin, F. ; Nicolas, E.

  • Author_Institution
    Telediffusion de France, Metz, France
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    287
  • Lastpage
    288
  • Abstract
    Broadcast towers are shared by numerous communication systems which generate a very complex electromagnetic environment, and have to comply with safety standards based on ICNIRP guidelines. To verify compliance with those limits, it is necessary to define a new selective isotropic and accurate probe.
  • Keywords
    broadcasting; calibration; electric field measurement; electric sensing devices; electromagnetic fields; phase measurement; safety; standards; ICNIRP guidelines; amplitude; broadcast towers; complex electromagnetic environment; electromagnetic fields; phase; safety standards; selective isotropic measuring system; selective isotropic probe; Antenna measurements; Broadcasting; Electromagnetic fields; Electromagnetic measurements; Electromagnetic scattering; Frequency; Magnetic field measurement; Phase measurement; Poles and towers; Probes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.850989
  • Filename
    850989