• DocumentCode
    2130061
  • Title

    DC voltage synthesis using a pulse-quantized Josephson voltage source

  • Author

    Benz, S.P. ; Christian, L.A. ; Burroughs, C.J. ; Hamilton, C.A.

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Boulder, CO, USA
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    339
  • Lastpage
    340
  • Abstract
    We have synthesized and measured DC voltages using a bipolar pulse-quantized Josephson voltage waveform synthesizer. Bias current ranges were determined for 101 equally spaced DC voltage steps between -18.6 and +18.6 mV. The flatness of a step at -7.444 mV was found to vary only 2.6 nV with a type A standard uncertainty of 1.6 nV. The linearity of a nanovoltmeter was investigated by synthesizing 11 different DC voltages.
  • Keywords
    measurement standards; superconducting arrays; superconducting junction devices; voltage measurement; waveform generators; -18.6 to 18.6 mV; DC accuracy; DC voltage synthesis; Josephson voltage standard; bias current ranges; bipolar voltage waveform synthesizer; equally spaced DC voltage steps; nanovoltmeter linearity; pulse-quantized Josephson voltage source; step flatness; type A standard uncertainty; Circuit synthesis; Clocks; Current measurement; DC generators; Electrical resistance measurement; Frequency synthesizers; Josephson junctions; Pulse measurements; Transmission line measurements; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.851014
  • Filename
    851014