DocumentCode
2131027
Title
Lightning, ground potential rise, and electrical damage; protecting wayside equipment on the MTA Long Island Rail Road
Author
Haluza, Doug
Author_Institution
MTA Long Isalnd Rail Road, Jamaica, NY, USA
fYear
1996
fDate
30 Apr-2 May 1996
Firstpage
111
Lastpage
135
Abstract
Rail transportation systems are particularly prone to lightning and electrical damage. The many interconnected wayside systems are environmentally exposed and geographically distributed. Physical separation and the necessary interconnecting cables make the various signal, communications and power systems prime targets for damage from ground potential differences. The MTA Long Island Rail Road (LIRR) provides an excellent case study for this subject. As the largest commuter railroad in the US, the LIRR has a very high density of electrical and electronic equipment located along its right-of-way. Although the incidence of lightning on Long Island is relatively moderate, earth ground disturbances are of a much higher magnitude, due to extremely poor soil conductivity. To address these issues, the LIRR Engineering Department formed a multi-disciplinary task force. Their investigations revealed that equipment damage had been incorrectly attributed to either lightning or DC traction power faults. Investigations showed the main cause was actually AC transmission and distribution line power faults, due to a lack of inductive coordination. This paper provides some background information on lightning, power faults, and ground potential differences, and summarizes the Railroad´s experience since it began seriously addressing these problems seven years ago
Keywords
data communication; distribution networks; electrical conductivity; electrical faults; lightning; lightning protection; power system protection; railways; rapid transit systems; signalling; soil; AC transmission line power faults; DC traction power faults; MTA Long Island Rail Road; communications systems; commuter railroad; distribution line power faults; earth ground disturbances; electrical damage; electronic equipment; ground potential rise; inductive coordination; interconnected wayside systems; lightning; poor soil conductivity; power systems; signal systems; wayside equipment protection; Communication cables; Conductivity; Electric potential; Electronic equipment; Lightning; Power engineering and energy; Power system interconnection; Power system protection; Rail transportation; Soil;
fLanguage
English
Publisher
ieee
Conference_Titel
Railroad Conference, 1996., Proceedings of the 1996 ASME/IEEE Joint
Conference_Location
Oakbrook, IL
Print_ISBN
0-7803-3351-9
Type
conf
DOI
10.1109/RRCON.1996.507966
Filename
507966
Link To Document