Abstract :
A resistance comparison carried out with a temperature and pressure stabilized 100 /spl Omega/ standard resistor was performed in November and December 1998. The participants were BIPM, BNM-LCIE (France), PTB (Germany) and VTT (Finland)-pilot. The comparison results agree within 4/spl middot/10/sup -9/ with a combined standard uncertainty of 11/spl middot/10/sup -9/.
Keywords :
electric resistance measurement; measurement standards; measurement uncertainty; quantum Hall effect; resistors; transfer standards; 100 ohm; AC-DC resistance standard; combined standard uncertainty; pressure stabilized; quantum Hall resistance standards; resistance bridge; resistance comparison; standard resistor; temperature stabilized; transfer resistor; Bridges; Control systems; Electrical resistance measurement; Laboratories; Q measurement; Resistors; Temperature control; Temperature sensors; Thermistors; Transportation;