  • Abstract
    The paper describes new techniques of measuring angular and in-phase errors of voltage dividers at frequencies up to 200 kHz. Preliminary investigations indicate uncertainties of 400 /spl mu/rad and 50 /spl mu/V/V at voltages up to 240 V and frequencies up to 200 kHz.
  • Keywords
    measurement errors; measurement standards; measurement uncertainty; power measurement; voltage dividers; 200 kHz; 240 V; ac power standard; capacitive divider; in-phase errors; measurement uncertainties; up to 200 kHz; voltage dividers; Artificial intelligence; Capacitance measurement; Electrical resistance measurement; Error correction; Frequency conversion; Frequency measurement; Phase measurement; Power measurement; Reactive power; Voltage;